Technical specifications Tehnični_list_AVC__krogelni_ventil_EN.pdf
Guidance AVC-z-krogelnim-ventilom_SLO_EN_DE.pdf
Photo AVC3p_krogelni_ventil.tif

Presentation

AVC and 3 W ball valve sets are designed to switch between different heat sources.

 

Application

  • Switching from a solid fuel boiler to an oil boiler.
  • Switching from a solid fuel boiler to a gas boiler.
  • Switching the reservoir to an oil boiler.
  • Switching the reservoir to a gas boiler.
  • Switching between a solid fuel boiler and a solar system (sanitary water preparation).
  • Switching between an oil boiler and a solar system (sanitary water preparation).
  • Switching between a heat pump and solar system (sanitary water preparation).
  • Switching between heating and preparation of hot sanitary water.
  • Switching collectors east/west.
  • Switching the hot sanitary water heater to the reservoir (solar system).
  • Switching the hot sanitary water heater to the swimming pool (solar system).
  • Switching between two heat exchangers.
  • As a switching element for cooling systems.
  • As a switching element in the processing industry and agriculture.

Advantages

  • Perfect seal.
  • Minimum resistance or flow reduction.
  • Suitable for use in household and commercial systems.
  • Suitable for use in the heating system, as well as in sanitary water systems.
  • Extremely simple and quick installation.
  • Indicator of the direction of rotation.
  • Indicator of the direction of rotation of the mixing valve.
  • Integrated permanent manual operation clutch.
  • The actuator is not damaged in case of valve blockage.

TYPICAL APPLICATIONAVCRS + 2-way ball valveAVCRS + 3-way ball valve
Switchover from a solid fuel boiler to an oil boiler 
Switchover from a solid fuel boiler to a gas boiler 
Switchover of the storage tank to an oil boiler 
Switchover of the storage tank to a gas boiler 
Switchover between a solid fuel boiler and a solar system (domestic hot water heating) 
Switchover between an oil boiler and a solar system (domestic hot water heating) 
Switchover of the heat pump and the solar system (domestic hot water heating) 
Switchover between heating and domestic hot water heating 
Switchover of the collectors east/west 
Switchover of the domestic hot water storage tank to the storage tank (solar system) 
Switchover of the domestic hot water storage tank to the pool (solar system) 
Switchover between two heat exchangers 
ON/OFF zone control of systems 
As a blocking element for heating systems 
As a blocking element for domestic hot water systems 
As a blocking element for cooling systems 
As a blocking element in processing industry and agriculture 

TECHNICAL SPECIFICATIONSAVC RS
Connection voltage230 V ~ or 24 V ~
Own consumption< 5 W
Standby consumption< 0.25 W
Auxiliary pump OFF switch250 V~, 3 A
Degree of protectionIP 42
Safety classII for the voltage of 230 V~
III for the voltage of 24 V~
Housing materialPC – dark grey
Standard cable length2 m
Operating temperature0÷50 °C
Storage temperature-20÷75 °C
Product weight390÷860 g
No. of pieces in the packaging unit12 pcs
Actuator dimensions with handle (W x H x D): 101 x 84 x 92 (99) mm
BALL VALVE 2 W
Operating temperature-20 ÷ 110 °C
Running angle90°
Dimensions1/2", 3/4", 1", 5/4"
BALL VALVE 3 W
Operating temperature-20 ÷ 110 °C
Running angle90°
Dimensions1/2", 3/4", 1"