Differential controller SGC67HV
- Overview
- Product range compare
- Hydraulic schemes
- Technical data
- Accessories
Presentation
SGC universal solar heating controllers are intended for the regulation of solar systems for hot water production as well as a support system for room heating. Advanced operation algorithms ensure an optimal usage of solar energy and allow for the regulation of energy efficient circulation pumps. The SGC controllers have integrated preset hydraulic systems that allow a fast and simple installation.
Application SGC67HV
- In hot water production systems with classic or vacuum collectors
- In hot water production systems with additional heat sources
- In supply device heating using solar heating system and additional heat sources
- In pool heating systems
- Single-stage supply device charging
- Two-stage supply device charging
Advantage SGC67HV
- 65 preset hydraulic diagrams,
- controllers with 3 free programmable outputs,
- rotation speed control of 2 classical pumps (RMP),
- rotation speed control of 2 energy-efficient pumps (PWM, 0–10 V),
- system regulation with 2 collector fields,
- system regulation with 3 heat storage tanks,
- startup wizard for an easy and quick startup of the device,
- measurement and display of the generated energy,
- solar system protection by overheating of collectors,
- diagnostics of operation by prompting to errors and exceeded temperatures,
- the SeltronHome platform connectivity allowing remote control via smartphone or tablet.
PRODUCT PERFORMANCE COMPARISON | SGC16H | SGC26H | SGC36HV | SGC67HV |
---|---|---|---|---|
APPLICATION | ||||
In domestic hot water heating systems with flat or vacuum collectors | ||||
In domestic hot water heating systems with auxiliary heat sources | ||||
In storage tank heating systems using a solar system and auxiliary heat sources | — | |||
In pool heating systems | — | |||
For a single-stage storage tank loading | — | — | ||
For a two-stage storage tank loading | — | — | — | |
TECHNICAL CHARACTERISTICS | ||||
No. of preset hydraulic schemes | 5 | 22 | 53 | 65 |
No. of mechanical relays | — | 1 | 1 | 4 |
No. of solid state relays | 1 | 1 | 2 | 2 |
No. of temperature sensor inputs | 6 | 6 | 6 | 7 |
Number of collector fields | 1 | 2 | 2 | 2 |
No. of storage tanks | 1 | 2 | 3 | 3 |
Measurement of the energy obtained (kWh) | ||||
Option for pulse meter flow measurement (l/min) | ||||
Possibility for flow measurement with a Vortex sensor VFS | — | — | ||
Speed control for energy-saving pumps (PWM, 0÷10 V) | 1 pump | 1 pump | 2 pumps | 2 pumps |
Speed control for standard pumps (RPM) | 1 pump | 1 pump | 2 pumps | 2 pumps |
Free programming option | — | 1 output | 2 outputs | 3 outputs |
SYSTEM CONTROL | ||||
Collector fields | 1 | 2 | 2 | 2 |
Storage tanks | 1 | up to 2 | up to 3 | up to 3 |
Solar system domestic hot water heating and an auxiliary heat source | — | |||
Heating support | — | |||
Pool heating | — | |||
Using a solid fuel boiler | — | — | — | |
Quick cold storage tank start function | — | — | — | |
HEAT SOURCE CONTROL | ||||
Flat or vacuum collectors | ||||
Solid fuel boiler | ||||
Solid fuel boiler with a pellet burner | — | |||
Liquid fuel boiler | — | |||
Combined boiler | — | |||
Gas flow boiler | — | |||
Heat pump | — | |||
Storage tank | ||||
Auxiliary heating using electric heater | — | |||
OPTIONS FOR SWITCHING ON ADDITIONAL ENERGY SOURCES | ||||
The controller features the option of an auxiliary source for heating the water to the minimum temperature | ||||
The option for starting the primary energy source immediately or only when the water cannot be heated in a certain period of time | — | |||
The option for configuring the time during which we allow water heating only by using collectors – the controller will not switch on the primary heat source if the calculations show that the water can be heated only by collectors | — | |||
OPERATING MODES WITH MULTIPLE HOT WATER BUFFER TANKS | ||||
Constant operation in the “OPTIMUM” mode means an optimum use of solar energy for heating all of the storage tanks taking into account the preferred storage tank | — | |||
The "AUTO" operation mode automatically switches between winter and summer modes according to a preset calendar | — | |||
Constant operation in the “SUMMER” mode means the heating of only the preferred storage tank, other storage tanks are heated only when the preferred one reaches the desired temperature | — | |||
Continuous operation in the “WINTER” mode means an alternating parallel heating of all storage tanks | — | |||
Heating of all storage tanks | — | |||
USER FUNCTIONS | ||||
Domestic hot water heating according to the time programme | ||||
Holiday operation mode | ||||
One-time domestic hot water heating | ||||
HEATING SYSTEM PROTECTION | ||||
Anti-legionella protection (for a controlled energy source) | ||||
Collector frost protection | ||||
Forced pump start at the highest collector temperature | ||||
Switching off of the pump when the safety temperature has been exceeded | ||||
Solar system protection when collectors are overheating | ||||
Storage tank overheating protection | ||||
Storage tank recooling to the desired temperature | ||||
Periodic starts of pumps during a period of inactivity | ||||
A COMPREHENSIVE OVERVIEW OF THE HEATING SYSTEM OPERATION | ||||
Graphic display of temperatures according to days of the last week | ||||
Detailed display of temperatures for the current day | ||||
Archiving and graphic display of the solar energy obtained | ||||
Notifications on the activated protection functions and warnings about system failures | ||||
Possibility to simulate sensors and analyse the system operation | ||||
REMOTE ACCESS | ||||
Possibility of USB connection to a PC | ||||
Connectivity to the SeltronHome platform providing remote control using a smartphone or tablet | ||||
SETUP AND INSTALLATION | ||||
Wizard for an easy and quick device start-up | ||||
13-language user interface Languages: EN, DE, FR, NL, PL, ES, SL, IT, CS, LT, GR, HU, HR | ||||
Setting up the operation by selecting the hydraulic scheme | ||||
“Help” button for quick help with the setup | ||||
Graphically adjustable time programmes | ||||
Option to simulate the system operation | ||||
Logging and display of changes made to the setup | ||||
Option for retrieval of the basic setup in the event of data loss or unwanted changes | ||||
Option for programming free outputs | ||||
Possibility of wall or DIN rail installation | ||||
Simple installation and connection |
Technical specifications | SGC67HV |
---|---|
Backlit graphic display | yes |
Operating hours meter | yes |
Weekly program timer | yes |
Connection voltage | 230 V~, 50 Hz |
Own consumption | 2.5 W |
Energy consumption in the standby mode | Max. 0.5 W |
No. of inputs | 7 pcs temperature sensor (Pt 1000) 1 pc pulse input |
Additional inputs | 1 pc Grundfos VFS flow meter |
No. of outputs | 2 pcs Triac for speed control (R2, R3) 4 pcs relay (R1, R4, R5, R6) 2 pcs PWM or analogue 0÷10 V (Y2, Y3) |
Relay outputs | 4 (1) A~, 230 V~ |
Triac outputs | 1 (1) A~, 230 V~ |
Clock power supply | Battery CR2032 (Li-Mn) 3 V |
Clock accuracy | +/-1 s (24 h) at 20 °C |
Degree of protection | IP20/EN60529 |
Safety class | I according to EN 60730-1 |
Operation mode | 1B according to EN 60730-1 |
Type of temperature sensors | Pt1000 or KTY10 |
Housing material | ASA – thermoplastic |
Permissible ambient temperature | 0÷40 °C |
Storage temperature | -20÷65 °C |
Product weight | 460 g |
No. of pieces in the packaging unit | 6 pcs |
Dimensions | ![]() |
Electrical connection |
Article - Nr. | Products | |
---|---|---|
![]() |
2SGC67HV00-010 | Differential controller SGC67HV⇲ |
![]() |
2SGC67HV50-010 | Differential controller SGC67H, with sensors (5xTF/Pt)⇲ |
![]() |
1TFPT-000 | Immersion temperature sensor TF/Pt⇲ |
![]() |
1VFPT-000 | Surface temperature sensor VF/Pt⇲ |
![]() |
1AVC0532M210-030 | Actuator AVC05, 3 point, 5 Nm, 2 min, 230 V~⇲ |
![]() |
1AVC0521M210-030 | Actuator AVC05R, 2 point, 5 Nm, 1 min, 230 V~⇲ |
![]() |
1SVC25+NN0 | SVC 25 impulse flow meter (up to 2.5m3/h, 40l/min) |
![]() |
1GWD2-040 | GWD2 Seltron home connection⇲ |
Sanitary water heating with classical or vacuum collectors.
Sanitary water heating with additional heat sources.
Storage tank heating with solar system and additional heat sources.
Swimming pool heating.
Single-stage storage tank charging.
Two-stage storage tank charging.
Related products

SGC36HV
Differential controller SGC36HV controls domestic hot water heating system with traditional or vacuum collectors, additional heat sources, single-stage buffer tank loading and heating of swimming pools.

SGC26H
Differential controller SGC26H controls domestic hot water heating systems with traditional or vacuum collectors and additional heat sources.

SGC16H
Differential controller SGC16H controls domestic hot water heating systems with traditional or vacuum collectors.